Grid infrastructureIndiaEIR-1266

Transformer fires and cable fault cause outages in Noida

June 2024Published 25 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
supply cut for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Transformer in Noida, India
What
Transformer fire after oil leak and cable fault from overheating
Response
Power officials disconnected the transformer
Cause
Overheating, oil leak, overload and higher demand in hot weather
Outcome
Outages of half an hour to more than four hours; water supply affected

A fire broke out in a transformer in Noida. A cable was damaged by overheating in Noida, and a transformer in Noida caught fire after an oil leak. Power officials disconnected the transformer, but outages continued the next day. Cuts of half an hour to more than four hours were reported in several Noida sectors, and in parts of Ghaziabad. Water supply was also affected in some places. An official said rising temperatures and higher demand had increased the load on substations, and that supply itself was not short.

The report links the faults to overheating, an oil leak, overload and higher demand in hot weather. Residents said they had warned of frequent cuts for more than a week.

  1. Inspect distribution transformers for oil leaks before peak summer load, as an oil leak led to a transformer fire.
  2. Track substation loading when demand rises with temperature, as overload from hot weather caused faults.
  3. Act on repeated local faults, as residents had warned of frequent cuts for more than a week.

More lessons on maintenance, inspection and ageing assets, weather and external hazards, emergency response and public communication, from every incident on the register.

  • Exact downtime of each affected substation
  • Model and age of the failed transformer
  • Cost of the damage and outages

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-25. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Grid infrastructure incidents in India, by year, free with a credit (PNG).

Grid infrastructure incidents in India: 90 entries, with a free alert for the next one.

Substation and transformer fires: the counts, the latest entries and a free alert for the next one. Also: power line and cable failures.

Browse the full register or submit an incident.