Grid infrastructure incidents

Safety incidents, near-misses and operational failures involving grid infrastructure assets, with lessons learned.

Substation and transformer fires: the counts, the latest entries and free alerts

By country

What fails in grid infrastructure

Where the reporting mentions a part, transformer is mentioned most often: in 554 of the 1150 entries, then cable or overhead line (182) and switchgear or breaker (59). In 456 entries the reporting mentions none of these parts. A mention is not a finding of fault.

Parts mentioned in the reporting

Part mentionedEntries
Transformer554
Cable or overhead line182
Switchgear or breaker59
Substation building or control room15
Reactor or capacitor10
Not stated456

Component and mode, from the classified records

Component and mode: 102 grid infrastructure records on the register have an approved record with a controlled component and mode, and 69 of those have no mode established in any public source. The component and mode of each record are in the paid record; these are the counts.

ComponentRecordsMode, where established
Transformer55electrical fault 10, external event 5
Switchgear or breaker20electrical fault 6, external event 2, control or software 1
Cable or connection4external event 2, human or procedural 1, electrical fault 1
Other part1external event 1
Not stated22external event 4

Questions answered

What fails most often in grid infrastructure?

Where the reporting mentions a part, transformer is mentioned most often: in 554 of the 1150 entries, then cable or overhead line (182) and switchgear or breaker (59). In 456 entries the reporting mentions none of these parts. A mention is not a finding of fault. Component and mode: 102 grid infrastructure records on the register have an approved record with a controlled component and mode, and 69 of those have no mode established in any public source. Each entry says what its sources established and nothing more.

What causes substation fires?

390 of the 1150 grid infrastructure entries are fires or thermal events. 699 electrical, 390 thermal / fire, 50 other, 6 mechanical, 3 near-miss, 2 gas release across the whole set. Where a fire service, regulator or operator stated a cause, the entry carries it and says who said it; where none did, the entry says so.

How many grid infrastructure incidents are on the register?

1150 entries from 87 countries, 2001 to 2026, 82 of them classed as major. Every entry is written from published reporting with its sources and is free to read.

Every grid infrastructure entry

1150 published entries. Newest first. Search and filter these in the register.

Get the next grid infrastructure incident by email

One email when a new incident is reported, at most two a day, plus a Monday digest. Free, no account needed, unsubscribe in one click.

We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By subscribing you agree to the privacy policy.

Every entry

Newest incident first. Search them, or narrow them by country, year or severity. Each entry is free to read, with what happened and its sources; the record behind it adds the cause where it is established, the part that failed, the downtime and the loss.

1,150 entries, showing the newest 20

See what failed, why, and what it cost

The record behind each entry: the manufacturer, integrator and operator, root cause, failure mode, downtime, losses and every source.

£39 a month

All 1,150 entries, with filters

Get the next grid infrastructure incident by email

One email when a new incident is reported, at most two a day, plus a Monday digest. Free, no account needed, unsubscribe in one click.

We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By subscribing you agree to the privacy policy.