Battery explosion at Port of Gandia Solar-Storage Site injures firefighter
Jan 2025Published 7 Sept 2026Responsible editor: Chief Editor
- Where
- Port of Gandia solar and storage installation, Valencia, Spain
- Operator
- Electromur
- What
- Explosion and fire in containerised lithium-ion battery
- Injuries
- One firefighter slight arm injury, treated on scene
- Cause
- Not reported
Get the next one by email
Free alerts on hybrid co-located incidents worldwide, and an email when EIR-0110 is updated. No account needed; unsubscribe in one click.
Confirm your email and every battery storage incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
Companies named in the reporting of this entry (being named is not a finding of fault): Electromur
What happened
An explosion and fire occurred in a containerised lithium-ion battery energy storage system colocated with a solar photovoltaic installation at the Port of Gandia solar and storage installation in Port of Gandia, Valencia, Spain, an installation integrated by Electromur. An explosion was heard in the early evening, prompting nearby residents to alert emergency services. Around twenty firefighters from several stations, along with police and health services, responded to the scene.
Toxic smoke from the burning battery container was visible for a considerable distance. Firefighters worked through the night to protect an adjacent warehouse storing combustible material and to bring the fire under control, which was achieved by the following morning. During firefighting operations, one firefighter sustained a slight arm injury and was treated and discharged at the scene. The battery system had been in operation for approximately two years at the time of the incident.
Contributing factors
The source does not specify a technical root cause for the explosion or fire in the battery container.
Lessons learned
- Toxic smoke from a lithium-ion battery fire can travel far, so operators must plan to alert residents and coordinate with multiple emergency units early.
- Battery fires next to combustible warehouses require clear protection protocols for adjacent assets during response.
- Explosion risk remains after ignition, so responders need standoff distances and protective equipment near battery containers.
More lessons on emergency response and public communication, spacing, layout and fire spread, from every incident on the register.
Not yet known
- Technical root cause of the explosion
- Battery container model and age
- Duration of site downtime
- Cost of damage and response
This entry is updated when these are reported. Get an alert for the next one like it.
Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.