Battery fire at solar-plus-storage site in Hongnong-eup, Yeonggwang-gun destroys modules
Nov 2024Published 7 Sept 2026Responsible editor: Chief Editor
- Where
- 1.6 MW solar facility in Hongnong-eup, Dandeok-ri, Yeonggwang-gun, Jeollanam-do, South Korea
- What
- Fire broke out in battery energy storage system
- Injuries
- None reported
- Response
- Fifteen fire engines and dozens of firefighters attended for five hours
- Cause
- Suspected overheating of lithium iron phosphate battery
Get the next one by email
Free alerts on hybrid co-located incidents in South Korea, and an email when EIR-0111 is updated. No account needed; unsubscribe in one click.
Confirm your email and every battery storage incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
What happened
In November 2024 a fire broke out in the afternoon at a battery energy storage system installed at a 1.6 MW solar power facility in Hongnong-eup, Dandeok-ri, Yeonggwang-gun, Jeollanam-do, South Korea. Around fifteen fire engines and dozens of firefighters attended, and the blaze was brought under control after approximately five hours. One battery storage building of about 42 square metres and roughly 560 battery modules were destroyed. No injuries were reported. The facility sits within about 200 metres of residential housing and a community centre for elderly residents, and the proximity of the installation to inhabited areas was raised locally following the fire.
Contributing factors
The source reported that the fire was suspected to have originated from overheating of a large-format lithium iron phosphate battery. The exact ignition mechanism was not confirmed in the source.
Lessons learned
- Large-format lithium iron phosphate batteries can overheat and cause fires that last several hours. Operators should install early detection and allow for extended cooling with many appliances.
- A battery storage building of 42 square metres can be fully destroyed. Operators should design separation to stop fire spread to nearby modules or inverters.
- Sites within 200 metres of housing need clear public risk plans. Operators should review smoke and gas dispersion with local authorities.
More lessons on detection and monitoring, spacing, layout and fire spread, emergency response and public communication, from every incident on the register.
Not yet known
- Exact ignition mechanism
- Battery model and age
- Downtime and repair cost
- Operator of the site
This entry is updated when these are reported. Get an alert for the next one like it.