Transformer fire at Kewatkhali substation disrupts Mymensingh power supply
Sept 2020Published 9 Nov 2026Responsible editor: Chief Editor
Get the next one by email
Free alerts on grid infrastructure incidents in Bangladesh, and an email when EIR-2843 is updated. No account needed; unsubscribe in one click.
Confirm your email and every substation and transformer incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
Companies named in the reporting of this entry (being named is not a finding of fault): Power Grid
What happened
A fire broke out at a transformer of a grid substation at the Kewatkhali power station in Mymensingh, Bangladesh, at about 10am on Thursday 10 September 2020. Two units of the Fire Service and Civil Defence attended and brought the blaze under control within 30 minutes. According to Power Grid Company of Bangladesh (PGCB), power supply to the neighbouring districts of Jamalpur, Sherpur and Netrakona in Mymensingh division was disrupted for one hour and then restored.
Supply in Mymensingh district remained cut off at the time of reporting while restoration work was under way. The same substation had suffered another fire on 8 September 2020, which also disrupted supply to Jamalpur, Sherpur and Netrokona districts. PGCB said action would follow an investigation into the cause of the fire.
Contributing factors
The cause of the fire was not reported and was to be established by investigation. The substation had already suffered a fire two days earlier.
Lessons learned
- A transformer that has caught fire at a substation should be inspected for insulation, oil and thermal faults before it is returned to full service, and a repeat fire should trigger a deeper investigation.
- Substations should have fire detection, automatic suppression or rapid-response arrangements that can limit a transformer fire to the unit affected.
- Network operators should plan switching and backfeed arrangements so that a single substation fault does not cut supply across several districts for an extended period.
More lessons on electrical protection and isolation, detection and monitoring, outages, backup supply and restoration, from every incident on the register.