Wind turbine fire destroys nacelle and blade at Bulgana Green Power Hub, Victoria

May 2025Published 8 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
turbine out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 11 other entries (being named is not a finding of fault)
Where
Bulgana Green Power Hub near Great Western, Victoria
Operator
Neoen
What
Fire destroyed nacelle and blade of one turbine
Injuries
None reported
Cause
Cause unknown

Companies named in the reporting of this entry (being named is not a finding of fault): Neoen, Siemens Gamesa, Tesla

A fire broke out in one of 56 Siemens Gamesa SG 3.4-132 turbines at the 194MW Bulgana Green Power Hub, operated and owned by Neoen, near Great Western, Victoria, which also hosts a 20MW Tesla battery storage system. The Country Fire Authority (CFA) attended overnight after the turbine's main body was reported alight, established safety zones and kept clear of the structure due to the fire risk from the height of the turbine.

Neoen, as site operator, was contacted and the turbines were shut down. Several hours later a blade caught fire, detached and fell to the ground. The fire destroyed the nacelle and the blade. Energy Safe Victoria investigators and engineers attended the scene and, at the time of reporting, the cause of the fire remained unknown. No injuries were reported and the wind farm was taken offline pending investigation. The fire began at about 9.30pm on 28 May 2025.

Seven Country Fire Authority units from the Ararat, Stawell and Great Western brigades attended, and crews were recalled at about 3.20am when the blade caught fire, detached and fell.

The cause of the fire had not been determined at the time of reporting; Energy Safe Victoria stated the cause was still unknown while its investigators and engineers were on site.

  1. A nacelle fire at hub height cannot be fought from the ground, so plans must rest on exclusion zones.
  2. Operators must have rapid shutdown protocols for handover to fire authorities during turbine fires.
  3. Burning blades can detach and fall, so response plans must include this risk.

More lessons on structural integrity and turbines, from every incident on the register.

  • Exact cause of the fire
  • Downtime and cost of the incident

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-08. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Wind (onshore) incidents in Australia, by year, free with a credit (PNG).

Wind (onshore) incidents in Australia: 17 entries, with a free alert for the next one.

Wind turbine fires: the counts, the latest entries and a free alert for the next one. Also: wind turbine blade failures and wind turbine nacelle fires.

Browse the full register or submit an incident.