Wind (offshore)TaiwanEIR-0167

Fire takes single turbine out of service at Greater Changhua 4 wind farm

Aug 2026Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
turbine out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 11 other entries (being named is not a finding of fault)
Where
Greater Changhua 4 offshore wind farm off Taiwan
Operator
Ørsted
What
Turbine fire after automatic trip on abnormal condition
Injuries
None reported
Cause
Under investigation

Companies named in the reporting of this entry (being named is not a finding of fault): Siemens Gamesa

In 2026, a turbine at Ørsted's Greater Changhua 4 offshore wind farm off Taiwan automatically tripped after its monitoring system detected an abnormal condition. The site team subsequently observed a fire on the turbine, which was extinguished a short time later. No personnel were injured. The turbine was shut down and isolated and a safety exclusion zone was established around it as a precaution, while the rest of the wind farm continued to operate normally. Ørsted, the operator and owner of the site, notified the relevant authorities and stakeholders and said it would investigate the cause with the turbine manufacturer, Siemens Gamesa, with an investigation plan and a repair plan prepared. The root cause remained under investigation at the time of reporting.

Not reported. The operator stated that the cause remained under investigation.

  1. Automatic monitoring that trips and isolates a turbine on abnormal conditions limits fire damage and allows the rest of the site to continue generating.
  2. A marine safety exclusion zone around an offshore turbine must be set quickly after a fire to protect vessels and personnel.
  3. Joint investigation and repair plans with the turbine manufacturer must be agreed in advance to speed recovery after an incident.

More lessons on detection and monitoring, investigation and fleet-wide checks, from every incident on the register.

  • Root cause of the fire
  • Turbine model and age
  • Duration of turbine outage
  • Cost of repair and lost generation

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Wind (offshore) incidents by year, free with a credit (PNG).

Wind (offshore) incidents in Taiwan: 4 entries, with a free alert for the next one.

Wind turbine fires: the counts, the latest entries and a free alert for the next one. Also: offshore wind incidents.

Browse the full register or submit an incident.