Sabotage-linked transformer fire shuts down Substation 16, Sug Il Juma, Tripoli

2026Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
supply cut for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Substation 16, Sug Il Juma, Tripoli, Libya
Operator
General Electricity Company of Libya (GECOL)
What
Transformer on Route 16 caught fire after public interference
Response
Security forces intervened to allow staff to reconnect
Cause
Unauthorised public attempts to restore power

Companies named in the reporting of this entry (being named is not a finding of fault): General Electricity Company of Libya

The General Electricity Company of Libya (GECOL) reported that on-duty personnel at Substation 16 in Sug Il Juma, Tripoli, Libya, were forcibly removed by members of the public, leading to the shutdown of the station. Lines automatically disconnected as a safety response and could not be restored until security forces intervened, allowing staff to return and reconnect the system. During the incident, a transformer on Route 16 caught fire, which GECOL attributed to unauthorised attempts by the public to restore power independently without coordination with grid operation and control teams.

GECOL confirmed it has launched an investigation, in coordination with relevant authorities, into this and other suspected acts of sabotage at several substations, warning that such interference could cause a complete grid collapse and total blackout across the network. The exact date of the incident is not stated in the source.

Public frustration over power outages leading to forced entry and interference at the substation, and unauthorised attempts to restore power without coordination with grid control teams.

  1. A transformer fire at a substation can follow unauthorised public interference with equipment, so operators should secure sites against forced entry and train staff on rapid isolation.
  2. Forced removal of on-duty personnel at a substation prevents safe restoration, so sites need security plans that protect control staff during unrest.
  3. Unauthorised restoration attempts at a substation can cause automatic disconnections and risk wider collapse, so operators must enforce that only control teams manage reconnection.

More lessons on electrical protection and isolation, theft, arson and site security, structural integrity and turbines, from every incident on the register.

  • Exact date of the incident
  • Transformer model and age
  • Duration of the shutdown
  • Cost of the damage

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Grid infrastructure incidents by year, free with a credit (PNG).

Grid infrastructure incidents in Libya: 2 entries, with a free alert for the next one.

Substation and transformer fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.