Clamp failure and coolant leak found during Moss Landing battery restart testing
2025Published 16 Sept 2026Responsible editor: Chief Editor
- Where
- Elkhorn Battery Energy Storage System, Moss Landing, California
- Operator
- PG&E
- Manufacturer
- Tesla
- What
- Clamp failure and coolant leak in one Megapack
- Injuries
- None reported
Get the next one by email
Free alerts on battery storage incidents in the United States, and an email when EIR-0877 is updated. No account needed; unsubscribe in one click.
Confirm your email and every battery storage incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
Companies named in the reporting of this entry (being named is not a finding of fault): Tesla, Vistra Energy
What happened
PG&E began returning its Elkhorn Battery Energy Storage System at Moss Landing, California to service on 1 June 2025, following an automatic shutdown on 16 January 2025 when the system's infrared fire detection picked up flames from a fire at the neighbouring Vistra Energy battery facility. During testing, PG&E identified a clamp failure and a subsequent coolant leak in one of the 256 Tesla Megapacks on site. PG&E said there were no injuries, power outages, smoke or fire associated with the clamp failure and coolant leak.
Tesla, which maintains the Elkhorn system for PG&E, has evaluated the failed clamp and is developing an inspection and repair plan. PG&E's best estimate for a return to service is now 30 June 2026. The system will remain electrically disconnected from the grid in a safe, idle state, apart from connecting to maintain at or near minimum state of charge, until repairs are completed.
Contributing factors
A clamp failure in one Megapack led to a coolant leak during the planned, staged restart and testing process that PG&E began after the extended shutdown caused by the neighbouring facility fire. The underlying cause of the clamp failure is not reported.
Lessons learned
- A clamp failure in a Tesla Megapack led to a coolant leak, so operators should inspect clamps on identical units before full reactivation after shutdown.
- Phased restart testing after an extended shutdown can reveal latent mechanical faults before they cause fire or outage.
- A single Megapack clamp failure warrants fleet-wide checks on the thermal management system to prevent repeats.
More lessons on maintenance, inspection and ageing assets, outages, backup supply and restoration, investigation and fleet-wide checks, from every incident on the register.
Not yet known
- Underlying cause of the clamp failure
- Turbine model and age
- Cost of the repairs
- Downtime duration details
This entry is updated when these are reported. Get an alert for the next one like it.
Source
Site page: Elkhorn Battery Energy Storage System (status, dates and other incidents)
Other entries that name Moss Landing
- New fire smoulders at Vistra Moss Landing battery site during cleanup
- Major fire at Moss Landing Energy Storage Facility, California, multi-day incident
- Battery storage fire reignites at Vistra's Moss Landing facility
- Megapack fire at PG&E Elkhorn Battery, Moss Landing, California
- Water based suppression system leak causes battery shorting at Moss Landing Phase II
Published 2026-09-16. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.