June 2025Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
supply cut for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Ayyanaroothu substation near Panneerkulam in Thoothukudi district, Tamil Nadu
Operator
Tangedco
What
Transformer caught fire following electricity leak
Response
Foam tenders from several stations responded for twelve hours
Cause
Alleged electricity leak

Companies named in the reporting of this entry (being named is not a finding of fault): Tangedco

A fire broke out at an electricity board substation at Ayyanaroothu near Panneerkulam in Thoothukudi district, Tamil Nadu, in the early hours of a Saturday morning. The substation, operated by Tangedco and commissioned in 2014, steps down power generated by wind and solar farms in the region. According to sources cited in the report, a transformer caught fire following an electricity leak at around 4am. The transformer held approximately 80,000 litres of oil, which fuelled the fire and allowed it to spread rapidly.

Foam tenders and fire vehicles from several stations, including Thoothukudi Thermal Nagar, NTPL and Tirunelveli, were called to the site. Officials built a sand barrier around the transformer to contain oil leakage. The fire was fully extinguished by around 4:30pm the same day, meaning the response and containment effort lasted roughly twelve hours.

An alleged electricity leak in a transformer is cited by sources as the initial cause; the large volume of transformer oil present (around 80,000 litres) contributed to the fire spreading and burning for an extended period.

  1. Large oil-filled transformers need robust leak detection and early alarms, as an electricity leak at 4am allowed ignition and rapid spread.
  2. Bunding or sand barriers around transformers limit the spread of burning oil and should form part of emergency plans.
  3. Substations with large oil inventories require coordinated multi-station foam response because full extinguishment can take twelve hours.

More lessons on detection and monitoring, spacing, layout and fire spread, fire suppression and firefighting, from every incident on the register.

  • Exact cause of the electricity leak
  • Transformer model and age
  • Downtime and cost of damage
  • Injuries if any

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Grid infrastructure incidents in India, by year, free with a credit (PNG).

Grid infrastructure incidents in India: 86 entries, with a free alert for the next one.

Substation and transformer fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.