Battery room fire at solar-plus-storage site in Iksan-si, South Korea

May 2022Published 7 Sept 2026Responsible editor: Chief Editor

Reported damageFrom the sourceHow? Know the real figure?
Figure hidden: shown to subscribersReported figure
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 8 other entries (being named is not a finding of fault)
Where
Eoryang-ri, Mangseong-myeon, Iksan-si, Jeollabuk-do, South Korea
What
Fire in battery energy storage system room
Injuries
None reported
Response
Flames controlled in 40 minutes, full suppression late that night
Cause
Under investigation

Companies named in the reporting of this entry (being named is not a finding of fault): Samsung SDI

A fire broke out in the battery energy storage system room of a solar power facility in Eoryang-ri, Mangseong-myeon, Iksan-si, Jeollabuk-do, South Korea, in the early afternoon. Fire crews brought the visible flames under control within about 40 minutes, but the battery fire continued to smoulder and took several more hours to fully extinguish, with full suppression achieved late that night. No injuries were reported. Around 60 square metres of the ESS room were burned, and local fire authorities estimated the property loss at roughly 200 million Korean won.

The cause of the fire was under investigation by fire and electrical safety authorities at the time of reporting, with battery manufacturer Samsung SDI stating that while the fire originated in the battery area, the underlying cause could lie elsewhere in the integrated system.

Not reported at time of publication; investigation into root cause was ongoing by fire authorities and the national electrical safety agency.

  1. Battery fires in enclosed ESS rooms can smoulder for hours after visible flames are suppressed, so operators must plan for extended monitoring and resources.
  2. Root cause analysis for ESS fires needs joint work by fire services and electrical safety regulators, as origin in the battery area may not mean the battery itself failed.

More lessons on detection and monitoring, fire suppression and firefighting, from every incident on the register.

  • Root cause of the fire
  • Battery model and age
  • Downtime and repair cost

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Hybrid co-located incidents in South Korea, by year, free with a credit (PNG).

Hybrid co-located incidents in South Korea: 20 entries, with a free alert for the next one.

Browse the full register or submit an incident.