Fire at Hyundai Steel indoor battery storage system, Incheon, South Korea

Sept 2022Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 8 other entries (being named is not a finding of fault)
Where
Hyundai Steel facility, Incheon, South Korea
What
Fire at indoor battery energy storage system
Injuries
One firefighter injured
Manufacturer
Samsung SDI
Cause
Not reported

Companies named in the reporting of this entry (being named is not a finding of fault): Hyundai Steel, Samsung SDI

In 2022, a fire was reported in the early morning at an indoor battery energy storage system installed at the Hyundai Steel facility in Incheon, South Korea. The system was used to charge overnight and discharge during the day for energy shifting. Crews from several fire stations attended and an escalated multi-agency response was declared shortly after the initial call. The fire was contained by responders and one firefighter was reported injured during the response.

Reporting at the time indicated that around one percent of the installed battery capacity was damaged. No fatalities were reported, and the cause was not disclosed in the available reporting. The battery system was supplied by Samsung SDI.

Not reported in available sources.

  1. Indoor BESS at industrial sites needs detection, suppression and ventilation sized for thermal runaway and gas build up.
  2. Agree escalated multi-agency response with local fire service before energisation, covering access and isolation.
  3. Early detection and module level isolation limits damage to a small share of capacity.

More lessons on detection and monitoring, fire suppression and firefighting, from every incident on the register.

  • Cause of the fire
  • Battery system model and age
  • Downtime and repair cost

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in South Korea, by year, free with a credit (PNG).

Battery storage incidents in South Korea: 35 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.