Battery storageSouth KoreaEIR-0649

Battery storage fire reported at Jinan-gun facility in South Korea

Jan 2025Published 11 Sept 2026Responsible editor: Chief Editor

Reported damageFrom the sourceHow? Know the real figure?
Figure hidden: shown to subscribersReported figure
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
ESS facility in Bugui-myeon, Jinan-gun, North Jeolla province, South Korea
What
Fire damaged part of facility ceiling, batteries and modules
Injuries
None reported
Response
Firefighters extinguished blaze after 3 hours 31 minutes
Cause
Under investigation

On 19 January 2025 at approximately 14:59, a fire broke out at an energy storage system (ESS) facility in Bugui-myeon, Jinan-gun, North Jeolla province, South Korea. The fire damaged part of the facility ceiling (approximately 3 square metres) as well as batteries and modules. Fire services estimated the property damage at around 6.1 million Korean won. No injuries were reported. Firefighters who responded to the report extinguished the blaze after approximately 3 hours and 31 minutes. Police and fire authorities were investigating the exact cause of the fire at the time of reporting. The facility name, operator, capacity and technology supplier were not disclosed in the source report.

Not reported. The exact cause of the fire was still under investigation by police and fire authorities at the time of publication.

  1. A battery storage fire can damage ceiling panels and modules, so operators should check fire resistance of building fabric around ESS units.
  2. Fire services can contain a battery storage fire within hours, so operators should plan rapid access routes and early detection systems.

More lessons on detection and monitoring, from every incident on the register.

  • Exact cause of the fire
  • Facility name, operator and capacity
  • Technology supplier and battery model

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-11. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in South Korea, by year, free with a credit (PNG).

Battery storage incidents in South Korea: 35 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.