Explosion and multi-day fire at SIN11 Digital Loyang 1 data centre, Singapore

Sept 2024Published 7 Sept 2026Updated 13 Oct 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
SIN11 Digital Loyang 1 data centre, 3 Loyang Way, Loyang, Singapore
Operator
Digital Realty
What
Explosion in lithium-ion BESS, multi-day fire in battery rooms
Injuries
None reported
Cause
Electrical issue in one battery room (provisional)

Companies named in the reporting of this entry (being named is not a finding of fault): Digital Realty

Also named in the reporting: Digital Realty

A fire alarm was triggered at SIN11 Digital Loyang 1, a multi-storey data centre at 3 Loyang Way, Loyang, Singapore, operated by Digital Realty, after an explosion occurred in a lithium-ion battery energy storage system used for uninterruptible power supply, located in battery rooms on the third floor. Approximately 20 occupants evacuated before fire crews arrived, and all site workers were evacuated shortly after the alarm. Fire services deployed four water jets, activated the building sprinkler system, and used an unmanned firefighting robot to cool the batteries.

The fire, which affected two battery rooms, two power supply rooms and an equipment storage area, took more than two days to be declared under control. A preliminary structural assessment found minor damage, including plaster delamination, paint peeling and soot, but no loss of overall structural integrity. Building authorities issued closure and dangerous building orders for affected areas as a precaution. Cloud service disruptions were reported by tenant organisations. No injuries were reported.

Early investigation by the fire authority indicated the fire was likely caused by an electrical issue in one of the battery rooms; this finding was described as provisional.

  1. Lithium-ion BESS in data centre battery rooms can sustain thermal runaway for days, so operators must plan for extended remote cooling with robots rather than direct entry.
  2. Unmanned firefighting robots allow safe cooling of battery fires without exposing crews to ongoing thermal runaway.

More lessons on fire suppression and firefighting, from every incident on the register.

  • Battery model and age
  • Exact duration of cloud service disruptions
  • Cost of damage and repairs

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Data centre incidents by year, free with a credit (PNG).

Data centre incidents in Singapore: 4 entries, with a free alert for the next one.

See UPS and battery room fires at data centres.

Browse the full register or submit an incident.