Battery room fire at Digital Realty data centre in Hillsboro, Oregon

May 2025Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Battery room at Digital Realty data centre, Hillsboro, Oregon, United States
What
Fire broke out in a battery room
Injuries
None reported
Response
Local fire service responded; fire burned for five hours
Cause
Under investigation

Companies named in the reporting of this entry (being named is not a finding of fault): Digital Realty

In May 2025 a fire broke out in a battery room at the Digital Realty data centre in Hillsboro, Oregon, United States, prompting a significant response from the local fire service. Crews arriving on scene found batteries alight, with the fire contained to a single room, though thick smoke spread through the wider building. All occupants were evacuated safely and no injuries were reported. Given the difficulty of extinguishing lithium-ion battery fires, the fire service adopted a defensive strategy, containing the fire and allowing the batteries to burn out rather than attempting direct suppression. The fire burned for approximately five hours before being declared over. The cause remained under investigation at the time of reporting.

Not reported.

  1. Lithium-ion battery fires in data centre battery rooms can last several hours, so operators should agree defensive containment tactics with the fire service in advance.
  2. Smoke from a battery room fire can spread through the wider building, so smoke migration paths must be assessed in the fire strategy.
  3. Evacuation plans for battery fires should account for smoke spread across the building rather than the fire location alone.

More lessons on fire suppression and firefighting, spacing, layout and fire spread, from every incident on the register.

  • Battery model and age
  • Cost of damage
  • Downtime of the data centre

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Data centre incidents in the United States, by year, free with a credit (PNG).

Data centre incidents in the United States: 49 entries, with a free alert for the next one.

See UPS and battery room fires at data centres.

Browse the full register or submit an incident.