Fire reportedly involving solar panels on a Milan building prompts evacuation
2026Published 3 Nov 2026Responsible editor: Chief Editor
Get the next one by email
Free alerts on solar PV incidents in Italy, and an email when EIR-2714 is updated. No account needed; unsubscribe in one click.
Confirm your email and every solar incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
What happened
A fire reportedly broke out at a building in via Volta, Milan, Italy, and involved the photovoltaic panels in the array. The source reports that the flames affected the module area, that the building was evacuated, and that about 20 square metres of panels were affected. The cause has not been established: attributing the origin to a fault would require examination of the components and the system documentation, and no such finding has been made public.
No estimate of roof damage has been published, and it has not been stated whether the affected part of the system has returned to service. The article gives no casualty figures and does not state the building's fire safety arrangements. Public information stops at clearing the area and making it safe after the fire was extinguished.
Contributing factors
Not reported. The source does not establish a cause or any contributing factor, and no examination findings have been published.
Lessons learned
- Keep records of the initial condition of a photovoltaic array, including module damage, internal condensation and fault-detection systems, and repeat thermographic inspection at intervals, with a fire-risk review after every modification.
- Provide a clearly marked isolation device protected from fire, with clear access for firefighters, that isolates the array from the DC generator as well as the AC supply.
- Keep at least 1 metre clear between panels, cables, inverters and distribution boxes and smoke and heat vents or other roof openings, and keep access paths free of components so crews can reach and isolate the system.
More lessons on detection and monitoring, fire suppression and firefighting, electrical protection and isolation, from every incident on the register.