Wind turbine blade falls after trailer overturns near Plettenberg

Oct 2026Published 16 Oct 2026Responsible editor: Chief Editor

Overnight, reported by police on 16 October 2026, the trailer of a heavy-load transporter left a gravel forest track near the Hohe Molmert wind park, near Plettenberg in the Märkischer Kreis, Germany. The trailer was carrying a wind turbine blade weighing about 135 tonnes, which was intended for installation at the park. During the transport towards the wind park the trailer overturned and the blade fell onto the forest floor.

Police were informed at 00:30. Two workers from Italy sustained minor injuries and were taken by ambulance to hospital for outpatient treatment. The fire brigade dealt with escaping operating fluids, the occupational safety authority was notified by police, and recovery was expected to take the whole day. The cause of the accident is still under investigation.

The cause of the accident has not yet been established according to the source. The trailer left a gravel forest track during the transport of a very heavy load to the site.

  1. Heavy-lift turbine component deliveries need route surveys that confirm the load-bearing capacity and gradient of unsurfaced access tracks before the move.
  2. Transport plans for blades and other oversized loads should include tracking and escort arrangements for the final approach to the site.
  3. Recovery of a fallen component can extend the exposure period for workers and emergency responders, so recovery plans should be agreed with the fire service and the authorities in advance.

More lessons on structural integrity and turbines, worker safety and safe systems of work, from every incident on the register.

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
turbine out of service for about •• daysShown in the record →Full estimate

Site page: Hohe Molmert (status, dates and other incidents)

Published 2026-10-16. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Wind (onshore) incidents in Germany, by year, free with a credit (PNG).

Wind (onshore) incidents in Germany: 27 entries, with a free alert for the next one.

Wind turbine fires: the counts, the latest entries and a free alert for the next one. Also: wind turbine blade failures.

Browse the full register or submit an incident.