Operator blames maintenance misconduct for UPS fire at data centre near Bamberg
Oct 2025Published 2 Oct 2026Updated 13 Oct 2026Responsible editor: Chief Editor
Get the next one by email
Free alerts on data centre incidents in Germany, and an email when EIR-1866 is updated. No account needed; unsubscribe in one click.
Confirm your email and every data centre incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
What happened
On 9 October 2025, at about 19:42, a fire broke out around the UPS system at the centron GmbH data centre in Hallstadt, near Bamberg in Bavaria, after maintenance work. The company said the fault involved the main low-voltage distribution board (NSHV) and the associated UPS system. An employee on site noticed the fire, raised the alarm and alerted the fire service, which arrived quickly and contained the fire using CO2 flooding.
Centron said no people were harmed. The company said its redundant infrastructure kept all services online without interruption. Its status page, however, apologised to customers who had experienced temporary interruptions or connection issues with certain services. Customers were notified by email at about 21:00. The site is a colocation facility of about 1.2 MW across 1,600 square metres, opened in 2014.
Contributing factors
Centron's root cause analysis attributes the disorder to human misconduct related to maintenance work. This is the operator's own finding. The source does not give a technical failure mechanism or any independent investigation.
Lessons learned
- Maintenance on low-voltage distribution boards and UPS systems should be checked by a second competent person before equipment is returned to service.
- Binding checklists that must be completed before recommissioning reduce the risk of errors being missed.
- Redundant architecture protects service but does not prevent a fire, so operators should verify that alarms and fire suppression respond as designed, and should notify customers promptly and keep status pages accurate about any impact.
More lessons on worker safety and safe systems of work, detection and monitoring, from every incident on the register.
Source
Site page: Data Center (status, dates and other incidents)
Published 2026-10-02. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.