Power failure at Regio IT data centre in Aachen disrupts councils' services

Mar 2026Published 12 Oct 2026Updated 13 Oct 2026Responsible editor: Chief Editor

At about 19:30 on Monday 2 March 2026 the power failed at the data centre of the municipal IT service provider Regio IT in Aachen, Germany. The emergency generator started, but it did not prevent damage. A central network component failed and the systems went down. Internal specialist applications, service portals and email access in about 100 municipalities in North Rhine-Westphalia were disrupted or completely unavailable until the morning of Wednesday 4 March.

Affected services included motor vehicle registration offices, job centres, residents' registration and citizen portals, and real-time bus stop displays in Aachen. Regio IT reported on 4 March that the fault had been fixed. The company told WDR that it was not yet clear how the outage could happen despite the emergency power supply, and questions from DataCenter-Insider went unanswered.

The sources do not establish why the emergency power supply did not prevent the outage. The cause of the failure of the central network component remained unexplained in the reporting. A council inquiry asks why the backup and redundancy systems did not work as intended, but no answer is recorded in the sources.

  1. Test the full transfer from grid power to generator under load, and check that network and distribution components downstream of the generator stay powered and working.
  2. Identify single points of failure in the power chain, including core network equipment, and hold spares or standby systems for them.
  3. Plan and rehearse restoration after a power event, and keep councils and customers informed through a status channel that does not depend on the failed systems.

More lessons on outages, backup supply and restoration, from every incident on the register.

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
out of service for about •• daysShown in the record →Full estimate

Published 2026-10-12. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Data centre incidents in Germany, by year, free with a credit (PNG).

Data centre incidents in Germany: 11 entries, with a free alert for the next one.

See backup generator failures at data centres.

Browse the full register or submit an incident.