Grid infrastructureAustraliaEIR-2183

Fire at Hornsby substation cuts power to 26,000 Sydney properties

Feb 2019Published 9 Oct 2026Responsible editor: Chief Editor

Companies named in the reporting of this entry (being named is not a finding of fault): Ausgrid

A fire broke out in the cable basement of the Hornsby power substation on Sydney's upper north shore just before midday on 13 February 2019, according to energy distributor Ausgrid. Smoke was reported coming out of the substation. About 26,000 properties across the upper north shore and Hills District lost power, including suburbs such as Hornsby, Waitara, Asquith, Hornsby Heights, Wahroonga, Galston, Thornleigh, Mount Colah and Normanhurst. Shops, restaurants and cafes closed during the lunchtime blackout, a pharmacy lost vaccines and antibiotics when its fridge stopped working, and traffic lights failed, so police were required to direct traffic. NSW Fire and Rescue attended. Ausgrid said crews were assessing the damage before restoring supply safely.

The source does not report the cause of the fire or the equipment involved beyond the cable basement.

  1. Operators of substations should assess how a loss of supply affects dependent services such as cold-chain storage for medicines and traffic signals, and plan backup power or public communication accordingly.
  2. Fire in cable basements and cable routes can disconnect large numbers of customers, so fire detection, segregation and fire-stopping of cable spaces should be reviewed.
  3. Early engagement with the fire service and a clear isolation plan are needed so that damaged equipment is made safe before supply is restored.

More lessons on outages, backup supply and restoration, detection and monitoring, fire suppression and firefighting, from every incident on the register.

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
supply cut for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden

Published 2026-10-09. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Grid infrastructure incidents in Australia, by year, free with a credit (PNG).

Grid infrastructure incidents in Australia: 22 entries, with a free alert for the next one.

Substation and transformer fires: the counts, the latest entries and a free alert for the next one. Also: power line and cable failures.

Browse the full register or submit an incident.