Wind (onshore)United KingdomEIR-1134

Wind turbine tower collapses at Kilgallioch Wind Farm, Ayrshire

Jan 2017Published 20 Sept 2026Responsible editor: Chief Editor

Reported damageFrom the sourceHow? Know the real figure?
Figure hidden: shown to subscribersReported figure
turbine out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 2 other entries (being named is not a finding of fault)
Where
Kilgallioch wind farm near Barrhill, Ayrshire
Operator
ScottishPower Renewables
Manufacturer
Gamesa
What
480-foot wind turbine tower collapsed during storm
Injuries
None reported

Companies named in the reporting of this entry (being named is not a finding of fault): Gamesa, ScottishPower Renewables

A 480-foot wind turbine at the Kilgallioch wind farm near Barrhill, Ayrshire, collapsed in the early hours of 13 January 2017 during a storm with 55mph gusts and snow squalls. The 160-tonne turbine, valued at around £2 million, had not yet been commissioned and was not generating electricity. According to a source cited by a local newspaper, the 328-foot tower creased at the access door near ground level before falling, scattering debris including three blades and switchgear over roughly half a kilometre.

No one was in the vicinity at the time and no injuries were reported. The operator, ScottishPower Renewables, did not publicly disclose the incident for seven days, prompting criticism from the local community. A joint investigation was launched by the operator and the turbine manufacturer, Gamesa, and the incident was reported to statutory authorities.

High winds of around 55mph combined with snow squalls at the time of the collapse; the turbine had not yet been commissioned or connected to the grid, and the cause of the structural failure at the tower's access door was under investigation.

  1. An uncommissioned wind turbine tower can still collapse in high winds, so operators must keep remote monitoring and weather response plans active before grid connection.
  2. Tower creasing at the access door shows that door cut-outs need extra reinforcement checks during fabrication and quality assurance.

More lessons on weather and external hazards, structural integrity and turbines, from every incident on the register.

  • Turbine model and age
  • Exact cause of the structural failure
  • Cost of debris clearance and replacement

This entry is updated when these are reported. Get an alert for the next one like it.

Site page: Kilgallioch wind farm (status, dates and other incidents)

Other entries that name Kilgallioch

Published 2026-09-20. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Wind (onshore) incidents in the United Kingdom, by year, free with a credit (PNG).

Wind (onshore) incidents in the United Kingdom: 48 entries, with a free alert for the next one.

Wind turbine fires: the counts, the latest entries and a free alert for the next one. Also: wind turbine blade failures and wind turbine collapses.

Browse the full register or submit an incident.