Poor installation blamed for two inverter fires at UK care home solar array
2026Published 20 Sept 2026Responsible editor: Chief Editor
- Where
- UK care home solar installation
- What
- One wall-mounted inverter caught fire twice
- Cause
- Not reported
- Outcome
- Site unable to monitor system performance
Get the next one by email
Free alerts on solar PV incidents in the United Kingdom, and an email when EIR-1133 is updated. No account needed; unsubscribe in one click.
Confirm your email and every solar incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
What happened
Electricians who inspected a UK care home's solar installation reported that one wall-mounted inverter had caught fire twice. The array is described as 228 panels rated at 445 watts each, about 101 kilowatts peak, feeding three 30-kilowatt inverters. The inspecting firm, Artisan Electrics, said it found several installation defects, including loose MC4 connectors, missing DC isolators on two of the three inverters and poor cable labelling. It also said the burned inverter had been swapped out before proper DC isolation was available, so workers reportedly had to cut live cables while arcing was visible, and that the replacement unit was never fully commissioned, leaving the site unable to monitor system performance effectively.
The care home, which has high round-the-clock electricity demand, was said to be still facing steep monthly power bills despite the size of the array. The date of the fires, the site name, the original installer and any fire service attendance are not reported.
Contributing factors
Reported by the inspecting electricians and not independently confirmed: loose MC4 connectors, missing DC isolators on two of three inverters, poor cable labelling, inadequate isolation arrangements during inverter replacement leading to live cables being cut with visible arcing, and incomplete commissioning of the replacement inverter.
Lessons learned
- Loose MC4 connectors on a solar PV array can cause arcing and fire, so operators should check all DC connections during routine inspections.
- Missing DC isolators on inverters force live cable cutting during replacement, so isolation equipment must be fitted before work starts.
- An uncommissioned replacement inverter leaves the array unmonitored, so full commissioning and monitoring must follow any swap.
More lessons on electrical protection and isolation, detection and monitoring, from every incident on the register.
Not yet known
- Date of the fires
- Site name
- Original installer
- Fire service attendance
This entry is updated when these are reported. Get an alert for the next one like it.
Source
Published 2026-09-20. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.