Poor installation blamed for two inverter fires at UK care home solar array

2026Published 20 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
UK care home solar installation
What
One wall-mounted inverter caught fire twice
Cause
Not reported
Outcome
Site unable to monitor system performance

Electricians who inspected a UK care home's solar installation reported that one wall-mounted inverter had caught fire twice. The array is described as 228 panels rated at 445 watts each, about 101 kilowatts peak, feeding three 30-kilowatt inverters. The inspecting firm, Artisan Electrics, said it found several installation defects, including loose MC4 connectors, missing DC isolators on two of the three inverters and poor cable labelling. It also said the burned inverter had been swapped out before proper DC isolation was available, so workers reportedly had to cut live cables while arcing was visible, and that the replacement unit was never fully commissioned, leaving the site unable to monitor system performance effectively.

The care home, which has high round-the-clock electricity demand, was said to be still facing steep monthly power bills despite the size of the array. The date of the fires, the site name, the original installer and any fire service attendance are not reported.

Reported by the inspecting electricians and not independently confirmed: loose MC4 connectors, missing DC isolators on two of three inverters, poor cable labelling, inadequate isolation arrangements during inverter replacement leading to live cables being cut with visible arcing, and incomplete commissioning of the replacement inverter.

  1. Loose MC4 connectors on a solar PV array can cause arcing and fire, so operators should check all DC connections during routine inspections.
  2. Missing DC isolators on inverters force live cable cutting during replacement, so isolation equipment must be fitted before work starts.
  3. An uncommissioned replacement inverter leaves the array unmonitored, so full commissioning and monitoring must follow any swap.

More lessons on electrical protection and isolation, detection and monitoring, from every incident on the register.

  • Date of the fires
  • Site name
  • Original installer
  • Fire service attendance

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-20. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Solar PV incidents in the United Kingdom, by year, free with a credit (PNG).

Solar PV incidents in the United Kingdom: 94 entries, with a free alert for the next one.

Solar farm fires: the counts, the latest entries and a free alert for the next one. Also: solar inverter fires.

Browse the full register or submit an incident.