Grid infrastructureRussiaEIR-1748

Fire reported at Vladivostok substations leaves homes without power

Jan 2024Published 1 Oct 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
supply cut for about •• daysShown in the record →Full estimate

Companies named in the reporting of this entry (being named is not a finding of fault): Far East Distribution Network

On 23 January 2024, explosions and fires were reported in Vladivostok, and hundreds of homes were left without power. Local reports said substations on Novozhilova Street and in Tikhaya Bukhta Bay were on fire, and media reported that more than 250 houses in Tikhaya Bukhta were de-energised. The Far East Distribution Network Company said that at about 19:00 two transformers were shut down at the Zagorodnaya substation in the Borisenko district, and that a fire was recorded in a closed distribution unit, not in the transformers.

It is not clear from this report whether that account describes the same sites named by residents. Power engineers and firefighters attended. The cause, any injuries, and how long the outage lasted were not reported.

Not reported. Local accounts of explosions and the company's account of a fire in a closed distribution unit have not been reconciled in this report.

  1. Early public accounts of which substations are on fire should be checked against the network operator before sites are treated as confirmed.
  2. A fire in a closed distribution unit can take transformers out of service even when the transformers themselves are not alight, so isolation and restoration plans should cover the switchgear as well as the transformers.
  3. Outage figures from residents and from the operator may differ, so operators should issue one early statement of the sites involved and the customers affected.

More lessons on emergency response and public communication, electrical protection and isolation, outages, backup supply and restoration, from every incident on the register.

Other entries that name Vladivostok

Published 2026-10-01. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Grid infrastructure incidents in Russia, by year, free with a credit (PNG).

Grid infrastructure incidents in Russia: 18 entries, with a free alert for the next one.

Substation and transformer fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.