Fire breaks out at Gunwi battery storage system in South Korea

Sept 2019Published 11 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 11 other entries (being named is not a finding of fault)
Where
Gunwi battery storage system, South Korea
Manufacturer
LG Chem
What
Fire in 1.5 MWh BESS during discharge
Injuries
None reported
Cause
Not reported

Companies named in the reporting of this entry (being named is not a finding of fault): LG Chem

On 29 September 2019, a fire occurred at a battery energy storage system in Gunwi, South Korea. The system, rated at 1.5 MWh and used for solar integration, was discharging at the time of the incident. The system used NMC cells manufactured by LG Chem and was approximately 1.8 years old at the time of the failure. According to the EPRI BESS Failure Incident Database, the fire resulted in damage to approximately 1.0% of the installed capacity. No further details on injuries, evacuation or emergency response were reported in the available source.

The source does not state a confirmed root cause. The system used nickel manganese cobalt (NMC) lithium-ion cells supplied by LG Chem and was in solar integration service at the time of the fire.

  1. NMC cells from LG Chem in solar integration service require checks on thermal monitoring during discharge.
  2. Damage limited to 1% capacity shows value of early isolation for BESS fires.

More lessons on detection and monitoring, electrical protection and isolation, from every incident on the register.

  • Confirmed root cause
  • Emergency response details
  • Cost of damage

This entry is updated when these are reported. Get an alert for the next one like it.

EPRI

Published 2026-09-11. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in South Korea, by year, free with a credit (PNG).

Battery storage incidents in South Korea: 35 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.