Fire at Musaga substation disrupts power in five counties
Aug 2026Published 7 Sept 2026Responsible editor: Chief Editor
- Where
- Musaga Substation in Kakamega
- Operator
- Kenya Power
- What
- Fire broke out on the night of 7 August
- Outcome
- Supply rerouted through six alternative substations
- Outcome
- 90 per cent of customers restored
Get the next one by email
Free alerts on grid infrastructure incidents in Kenya, and an email when EIR-0187 is updated. No account needed; unsubscribe in one click.
Confirm your email and every substation and transformer incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
Companies named in the reporting of this entry (being named is not a finding of fault): Kenya Power
What happened
A fire broke out at the Musaga Substation in Kakamega on the night of 7 August, affecting electricity supply across Kakamega, Bungoma, Busia, Siaya and parts of Vihiga counties. Kenya Power rerouted supply through six alternative substations: Webuye, Mumias, Eldoret, Kitale, Kisumu and Rang'ala. Approximately 90 per cent of customers were restored, though some continued to experience low voltage under the temporary arrangements. Personnel worked to recover damaged control and protection cables, to lay new cables for protection on the 132/33kV lines serving Tororo, Webuye, Lessos and Mumias, and to secure replacement transformers so the substation could return to full capacity.
Lessons learned
- A substation fire requires pre-planned reroutes through multiple neighbouring sites to limit outages across several counties.
- Fire damage to control and protection cables on 132/33kV lines delays full restoration until new cables are laid.
- Temporary supply arrangements after a substation fire can leave some customers with low voltage until replacement transformers arrive.
More lessons on emergency response and public communication, electrical protection and isolation, outages, backup supply and restoration, from every incident on the register.
Not yet known
- Cause of the fire
- Age of the substation equipment
- Cost of cable and transformer replacement
- Time until full capacity was restored
This entry is updated when these are reported. Get an alert for the next one like it.