Register / Solar PV / EIR-2682
← Back to the list
Solar PVItalyEIR-2682

Fire at Italian poultry farm probably started in photovoltaic system

2023Published 31 Oct 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
out of service for about •• daysShown in the record →Full estimate

A fire broke out in a layer poultry shed in Volpago del Montello, in the province of Treviso, Italy, reported on 9 August 2023. The local fire department said the flames had probably broken out from the photovoltaic system and had burned the insulating cover of the structure, which covered more than 1,500 square metres. The smoke asphyxiated the tens of thousands of laying hens in the shed. Firefighters from Montebelluna, Castelfranco and Treviso attended with three fire trucks and 16 operators to extinguish the blaze. The cause had not been determined when the report was published. Local sources reported that more than 20,000 hens were killed by the smoke.

The cause had not been determined when reported. The fire department said the flames had probably broken out from the photovoltaic system. The insulating cover of the structure burned, producing a considerable amount of smoke that killed the birds. The source does not state where the photovoltaic system was mounted.

  1. Photovoltaic systems on agricultural buildings should be inspected regularly for electrical faults, including DC cabling, connectors and inverters, because a fault can ignite the building structure.
  2. Livestock sheds need smoke ventilation and fire compartmentation planning, since smoke caused the animal losses in this incident.
  3. Solar arrays should have clearly marked isolation points and emergency shutdown procedures, and operators should share these with farm owners and fire crews so the array can be made safe quickly.

More lessons on maintenance, inspection and ageing assets, emergency response and public communication, worker safety and safe systems of work, from every incident on the register.

Published 2026-10-31. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Solar PV incidents in Italy, by year, free with a credit (PNG).

Solar PV incidents in Italy: 18 entries, with a free alert for the next one.

Solar farm fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.