Wind (onshore)SwedenEIR-0909

Crane boom collapses while lifting turbine nacelle at Swedish wind farm

Aug 2017Published 16 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
turbine out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 30 other entries (being named is not a finding of fault)
Where
Solberg wind farm near Åsele, Västerbotten, Sweden
Owner
Viatron owned the crane
Manufacturer
Liebherr LG1750 crane and Vestas turbine
What
Crane boom collapsed while lifting nacelle
Injuries
Crane operator minor leg injuries; two workers minor injuries

Companies named in the reporting of this entry (being named is not a finding of fault): Liebherr, Skelleftea Kraft, Vestas

The boom of a 750 tonne Liebherr LG1750 mobile crane, reportedly owned by Polish company Viatron, collapsed while lifting the nacelle of a Vestas wind turbine at the Solberg wind farm near Åsele, in Västerbotten, Sweden. The nacelle had only been raised a short distance off the ground when the boom went over the rear of the crane, reportedly after a loud noise and a sudden recoil. The crane operator jumped clear of the cab and suffered minor leg injuries.

Two other workers on the ground also sustained minor injuries; one was taken to hospital for a precautionary X-ray. The crane base itself remained stable after the collapse. The incident occurred around 10:00 am. The wind farm, which will comprise 22 turbines, is being developed with funding from Skelleftea Kraft and Fortum, with Vestas and Arise providing project management services during construction.

Not officially reported. The crane was working with main boom, regular counterweight and a suspended counterweight, but no confirmed cause such as wind speed, load weight, ballast configuration or lift radius has been published.

  1. A mobile crane boom can recoil over the rear during a nacelle lift, so the operator must have a clear escape path from the cab.
  2. Boom failure can occur even with main boom, regular counterweight and suspended counterweight fitted, so each configuration needs independent verification.
  3. Ground workers can be hit by a falling boom, so exclusion zones must extend beyond the load drop area to the full boom reach.

More lessons on structural integrity and turbines, worker safety and safe systems of work, from every incident on the register.

  • Confirmed cause of the boom collapse
  • Wind speed during the lift
  • Load weight and lift radius used
  • Downtime and repair cost

This entry is updated when these are reported. Get an alert for the next one like it.

Site page: Solberg wind farm (status, dates and other incidents)

Published 2026-09-16. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Wind (onshore) incidents in Sweden, by year, free with a credit (PNG).

Wind (onshore) incidents in Sweden: 10 entries, with a free alert for the next one.

Wind turbine fires: the counts, the latest entries and a free alert for the next one. Also: wind turbine nacelle fires and wind turbine collapses.

Browse the full register or submit an incident.