Battery storage fire destroys solar site ESS in Yeongju, South Korea

Nov 2018Published 11 Sept 2026Responsible editor: Chief Editor

Reported damageFrom the sourceHow? Know the real figure?
Figure hidden: shown to subscribersReported figure
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
solar power facility in Jangsu-myeon, Yeongju, North Gyeongsang Province, South Korea
What
fire in 33 square metre building housing ESS on standby
Injuries
None reported
Response
fire extinguished within about an hour
Cause
Under investigation

At around 3:55pm on 12 November 2018, a fire of unknown cause broke out at a solar power facility in Jangsu-myeon, Yeongju, North Gyeongsang Province, South Korea. The fire occurred in a 33 square metre sandwich panel building housing an energy storage system (ESS) that was on standby after charging. All 374 lithium-ion batteries installed in the ESS were burned. The fire was extinguished within about an hour. The fire department estimated property damage at approximately 702.25 million won. The solar facility, rated at 1,500 kW, had received its generation licence in July of the previous year. No injuries were reported in connection with this incident.

The exact cause of the fire was not determined at the time of reporting. Local reporting noted that solar and ESS facilities in the region lacked specific firefighting standards, and that lithium-ion battery fires can reach temperatures that standard gas-based fire suppression systems cannot cool.

  1. Gas-based suppression in lithium-ion ESS may fail to cool thermal events, so operators should fit systems rated for battery fires.
  2. ESS in solar sites without tailored standards need updated detection before standby fires spread to all cells.

More lessons on fire suppression and firefighting, detection and monitoring, from every incident on the register.

  • Exact cause of the fire
  • Battery model and age
  • Downtime of the 1,500 kW solar facility

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-11. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in South Korea, by year, free with a credit (PNG).

Battery storage incidents in South Korea: 35 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.