ESS fire at solar facility in Chilgok, South Korea

May 2019Published 11 Sept 2026Responsible editor: Chief Editor

Reported damageFrom the sourceHow? Know the real figure?
Figure hidden: shown to subscribersReported figure
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 11 other entries (being named is not a finding of fault)
Where
Gasa-myeon, Chilgok-gun, North Gyeongsang Province, South Korea
Manufacturer
LG Chem
What
fire in energy storage system at solar facility
Cause
Under investigation
Outcome
610 million won property damage

Companies named in the reporting of this entry (being named is not a finding of fault): LG Chem

A fire broke out at approximately 3:40 p.m. on 4 May 2019 at a solar power generation facility in Gasa-myeon, Chilgok-gun, North Gyeongsang Province, South Korea. The local fire department estimated property damage at around 610 million won and suspected the fire originated in the site's energy storage system (ESS), which used batteries manufactured by LG Chem. The facility, which began operating in February 2017, had temporarily halted ESS operation following a government recommendation late the previous year that all ESS facilities at risk of fire spread be shut down.

According to reports, some batteries within the ESS had been replaced the previous month and the system was being restarted when the fire occurred. This was reported as the 22nd ESS fire in South Korea since August 2017. A joint industry-government investigation team and the National Forensic Service conducted a site examination, with a full cause report expected the following month.

The fire occurred during restart of the ESS following partial battery replacement, after the system had been shut down in line with a government recommendation addressing a wider pattern of ESS fires across the country.

  1. Restart of an ESS after partial battery replacement must use staged checks and monitoring, as the fire started during restart following replacement.
  2. A pattern of 22 ESS fires since 2017 requires fleet-wide root cause work rather than isolated fixes.

More lessons on detection and monitoring, electrical protection and isolation, from every incident on the register.

  • Exact cause of the fire
  • ESS battery model and age
  • Duration of downtime

This entry is updated when these are reported. Get an alert for the next one like it.

Other entries that name Chilgok

Published 2026-09-11. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in South Korea, by year, free with a credit (PNG).

Battery storage incidents in South Korea: 35 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.