Battery compartment fire during commissioning at Hainan Tianneng Yingge Haiyanchang storage station
Oct 2022Published 11 Sept 2026Responsible editor: Chief Editor
- Where
- Hainan Tianneng Yingge Haiyanchang storage station, Yinggehai, Hainan, China
- Operator
- Hainan Tianneng Electric Power
- What
- Fire in battery compartment No. 6 of 25MW/50MWh BESS
- Injuries
- None reported
- Cause
- Not reported
Get the next one by email
Free alerts on battery storage incidents in China, and an email when EIR-0659 is updated. No account needed; unsubscribe in one click.
Confirm your email and every battery storage incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
Companies named in the reporting of this entry (being named is not a finding of fault): Hainan Tianneng Electric Power, PowerChina Hainan Electric Power Design
What happened
At around 18:30 on 20 October 2022, a fire broke out in one of ten battery compartments (No. 6) at the 25MW/50MWh energy storage system forming part of the Hainan Tianneng Yingge Haiyanchang 100MW photovoltaic project energy storage power station in Yinggehai, Hainan, China. The local fire department was notified and firefighters arrived at the site by 18:50. There were no casualties. The energy storage system was still in the commissioning stage, had not been connected to the grid or handed over from the EPC contractor, PowerChina Hainan Electric Power Design, to the operator, Hainan Tianneng Electric Power, so the incident did not affect grid operation.
Technical staff advised that the fire could not be safely extinguished with water at the scene. Because the burning compartment did not threaten surrounding equipment, the decision was taken to let the fire burn itself out before further disposal action.
Contributing factors
The battery system was in the commissioning phase and had not yet been formally handed over to the operator, Hainan Tianneng Electric Power. Reports noted that the site had recently conducted photovoltaic fire emergency drills but appeared to lack specific emergency drills and plans for energy storage battery fires.
Lessons learned
- Battery energy storage systems need fire emergency drills and response plans specific to the chemistry, separate from generic photovoltaic plans.
- Fires can occur during commissioning before handover or grid connection, so protocols must include dedicated fire monitoring and response.
- Water may not be safe or effective for lithium iron phosphate battery fires; agree tactics in advance, including controlled burn-out if isolation is assured.
More lessons on emergency response and public communication, detection and monitoring, electrical protection and isolation, from every incident on the register.
Not yet known
- Cause of the fire
- Battery compartment model and age
- Cost of the damage
- Duration of any downtime
This entry is updated when these are reported. Get an alert for the next one like it.