Battery storageSouth KoreaEIR-0658

ESS fire at Yeongam Solar Power Complex, Daemyung Energy, South Korea

Dec 2022Published 11 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Yeongam solar power complex, Yeongam-gun, South Korea
Operator
Daemyung Energy
What
Fire broke out in one of 24 ESS buildings on 27 December 2022
Injuries
None reported
Response
Yeongam Fire Station sent 21 vehicles and 45 personnel

Companies named in the reporting of this entry (being named is not a finding of fault): Daemyung Energy

A fire broke out at 4:28pm on 27 December 2022 in one of 24 energy storage system (ESS) buildings at the Yeongam solar power complex, operated by Daemyung Energy in Geumjeong-myeon (Geummyeon-myeon), Yeongam-gun, Jeollanam-do, South Korea. The site combines a 94MW solar array with a 251MWh battery storage system used to shift peak generation for grid balancing. The fire was contained to one of the 24 ESS buildings, each of reinforced concrete construction.

The Yeongam Fire Station dispatched 21 vehicles, including pump and chemical trucks, and 45 personnel. Fire officials stated that because it was a battery fire, efforts focused on preventing spread rather than extinguishing it directly, allowing it to burn out. Casualties were not reported in the source. This was the same site where a separate ESS fire occurred in June 2018, linked to a wind farm battery installation, which destroyed a 12MWh battery, a 4MW power conversion system and a building.

The site had previously experienced an ESS fire in 2018 linked to a co-located wind farm battery system. Industry commentary cited in the source suggested that battery aging, insufficient continuous monitoring and inadequate separation between ESS buildings were contributing risk factors in recurring ESS fires nationally, though no official cause had been confirmed for this specific incident at the time of reporting.

  1. Prior ESS fires at the same site call for extra monitoring and separation checks to limit repeat events.
  2. Reinforced concrete ESS buildings can contain a battery fire to one unit when spread is prevented.
  3. Battery fires require plans for burn-out periods as direct extinguishing is not used.

More lessons on detection and monitoring, spacing, layout and fire spread, fire suppression and firefighting, from every incident on the register.

  • Official cause of the fire
  • Battery model and age
  • Duration of downtime
  • Cost of the damage

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-11. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in South Korea, by year, free with a credit (PNG).

Battery storage incidents in South Korea: 35 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.