Battery cabinet fire during grid connection test at Lanyu Power Plant

Dec 2023Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Lanyu Power Plant, Lanyu, Taitung County, Taiwan
Operator
Taipower
What
Battery cabinet fire during grid connection test
Injuries
None reported
Cause
Suspected short circuit during grid connection test

A battery cabinet installed outside the Lanyu Power Plant on Lanyu (Orchid Island), Taitung County, Taiwan, operated by Taipower, caught fire during testing of a newly added energy storage system. The fire is suspected to have been caused by a short circuit that occurred while the system was undergoing a grid connection test. Plant staff and testers acted quickly to contain the blaze, and the local fire brigade was called to monitor the area to prevent the fire spreading to nearby facilities.

Because the battery chemistry involved is not suitable for direct water suppression, firefighters used metal fire extinguishers and cooling measures instead of hoses, and kept watch on the site for around one day until the situation was fully controlled. The plant's normal operations were not affected by the incident, and no injuries were reported.

A suspected short circuit occurring during commissioning or grid connection testing of the newly installed battery storage system. The lithium ion battery chemistry involved is incompatible with direct water-based firefighting, requiring alternative suppression methods.

  1. Battery cabinets in new storage systems can short circuit during grid connection tests, so operators must add close supervision and monitoring throughout commissioning.
  2. Lithium ion battery fires cannot use water hoses, so response plans must specify metal extinguishers and controlled cooling from the outset.
  3. Island sites need pre-agreed local response plans with battery operators because logistics slow external help.

More lessons on detection and monitoring, fire suppression and firefighting, from every incident on the register.

  • Exact cause of the short circuit
  • Battery cabinet model and age
  • Cost of damage and response

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents by year, free with a credit (PNG).

Battery storage incidents in Taiwan: 3 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one. Also: battery storage container fires.

Browse the full register or submit an incident.