Fire at a solar PV equipped house in Stoney Stratton

May 2025Published 28 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hidden
Where
detached timber-clad house in Stoney Stratton, near Evercreech, Somerset
What
fire involving solar PV
Response
Devon and Somerset Fire and Rescue Service attended and isolated supply
Cause
accidental
Outcome
ground floor, first floor and roof 50 per cent damaged by fire

Companies named in the reporting of this entry (being named is not a finding of fault): National Grid

On 11 May 2025, Devon and Somerset Fire and Rescue Service attended a fire at a detached timber-clad house in Stoney Stratton, Somerset. The first crew reported smoke, and all persons were accounted for. Crews isolated the electricity supply and worked in the roof space. Incident commanders requested PV Stop, a sprayable liquid carried on the service's aerial ladder appliances to block power generation from photovoltaic panels, and also requested National Grid.

They asked for the number of fire engines to be increased to eight pumps, and requested an aerial ladder platform and a water bowser. An incident command unit was mobilised. Thirty breathing apparatus wearers were used, with hose reel jets, main jets, a ground monitor and ladders. The service later confirmed a two-storey property measuring 25 m by 15 m, with the ground floor, first floor and roof 50 percent damaged by fire and 100 percent damaged by smoke.

The fire was confirmed as accidental. The log does not say whether the panels started the fire, whether PV Stop was applied, or how the panels themselves were damaged.

Not reported. The service confirmed an accidental fire but did not state an ignition point or whether the photovoltaic panels, inverter or cabling were involved.

  1. At a house fire where photovoltaic panels may still generate, isolate the grid supply early and have a means of stopping panel generation available.
  2. A well developed timber-clad roof fire can need many breathing apparatus wearers, thermal imaging and ladder access, so relief and welfare should be planned from the start.
  3. Call the network operator when on-site isolation may not stop generation from the panels.

More lessons on electrical protection and isolation, detection and monitoring, from every incident on the register.

  • What started the fire
  • Whether solar panels were the point of origin
  • Whether anyone was injured
  • Cost of the damage

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-28. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Solar PV incidents in the United Kingdom, by year, free with a credit (PNG).

Solar PV incidents in the United Kingdom: 97 entries, with a free alert for the next one.

Solar farm fires: the counts, the latest entries and a free alert for the next one. Also: rooftop solar fires.

Browse the full register or submit an incident.