Battery storageUnited StatesEIR-0930

Owner alleges defects, inverter failures and arc flashes at Diablo battery project

2022Published 17 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersLow confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Diablo battery storage project, 200 MW in Pittsburg, California
What
27 inverter failures and two arc flash events after April 2022
Injuries
None reported
Cause
Not reported

Companies named in the reporting of this entry (being named is not a finding of fault): Fluence

Energy-Storage.News reports a California court filing in which the owner of the Diablo battery storage project, a 200 MW system in Pittsburg, California, alleges technical failures after it took control following completion in April 2022. The filing alleges slow or inaccurate control responses to CAISO signals and removal from the ancillary service market for several weeks, an inoperable human-machine interface, frequent auxiliary-control and inverter failures, including an alleged 27 inverter failures between 13 June and 14 July 2022, two arc flash events, overheating and maintenance downtime. Fluence, the engineering, procurement and construction contractor, denies the allegations. Injury, damage and an independently confirmed cause have not been reported.

The owner attributes the alleged failures to workmanship and other shortcomings under the EPC contract. Fluence denies that account. No independent finding of cause has been reported.

  1. Inverter failures at a BESS must be logged against dispatch records, as slow responses led to removal from ancillary service markets for several weeks.
  2. Repeated inverter failures and arc flash events at battery sites require prompt investigation and a safe operating plan while the cause remains unconfirmed.

More lessons on worker safety and safe systems of work, from every incident on the register.

  • Cause of the inverter failures and arc flashes
  • Turbine or inverter model and age
  • Duration of maintenance downtime
  • Cost of the damage and lost revenue

This entry is updated when these are reported. Get an alert for the next one like it.

Site page: Diablo Energy Storage (status, dates and other incidents)

Published 2026-09-17. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in the United States, by year, free with a credit (PNG).

Battery storage incidents in the United States: 52 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.