Wind (onshore)IrelandEIR-0919

Vestas turbine collapses in high winds at Loughderryduff wind farm, Donegal

Mar 2013Published 16 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersHigh confidence
turbine out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenThe maker is named in 30 other entries (being named is not a finding of fault)
Where
Loughderryduff wind farm near Ardara and Glenties in County Donegal
What
Vestas V52-850kW wind turbine collapsed in high winds
Injuries
None reported
Cause
Under investigation
Owner
North West Wind Limited

Companies named in the reporting of this entry (being named is not a finding of fault): North West Wind, Vestas

A Vestas V52-850kW wind turbine at the Loughderryduff wind farm, near Ardara and Glenties in County Donegal, collapsed at approximately 17:00 on 21 March 2013 during what Vestas described as very high winds, reported at around 25 m/s (56mph). Wreckage was strewn over a wide area. No one was injured. Vestas, the turbine manufacturer, confirmed the collapse and said the remaining eight V52-850kW turbines at the site were shut down as a precaution while its technicians attended, and that the situation was under control.

Vestas said a thorough investigation would be conducted with an independent third party to establish the root cause, and that it could not speculate on the cause until that was complete. The site is owned by North West Wind Limited. Local people noted that the collapsed turbine stood on a flat plain about 50m above sea level, lower than other turbines proposed nearby.

Wind speeds of approximately 25 m/s (56mph) were reported at the time of the collapse. The root cause had not been established at the time of reporting and was the subject of a pending investigation by Vestas with an independent third party.

  1. A Vestas V52 turbine collapse in winds of 25 m/s requires operators to review structural and wind loading assumptions for the same model across their fleet.
  2. After one V52 turbine fails in high winds, shut down other V52 units at the same site until checks are complete.
  3. Structural failure of a V52 turbine needs an independent third-party root cause study to inform other owners of the model.

More lessons on structural integrity and turbines, from every incident on the register.

  • Root cause of the collapse
  • Turbine age and service history
  • Duration of site shutdown
  • Cost of damage and debris removal

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-16. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Wind (onshore) incidents by year, free with a credit (PNG).

Wind (onshore) incidents in Ireland: 3 entries, with a free alert for the next one.

Wind turbine fires: the counts, the latest entries and a free alert for the next one. Also: wind turbine collapses.

Browse the full register or submit an incident.