Battery storageSouth KoreaEIR-0669

Battery storage fire destroys energy storage room at solar site in Cheonan

Nov 2018Published 11 Sept 2026Responsible editor: Chief Editor

Reported damageFrom the sourceHow? Know the real figure?
Figure hidden: shown to subscribersReported figure
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Solar power facility in Mokcheon-eup, Dongnam-gu, Cheonan-si, South Korea
What
Fire destroyed 187 lithium-ion battery units in energy storage room
Injuries
None reported
Response
Firefighters extinguished the blaze within approximately two hours
Cause
Under investigation

At around 4:03pm on 12 November 2018, a fire broke out at a solar power facility in Mokcheon-eup, Dongnam-gu, Cheonan-si, South Chungcheong Province, South Korea. The fire involved the site's energy storage room and destroyed 187 lithium-ion battery units. Firefighters extinguished the blaze within approximately two hours. There were no injuries or fatalities reported. Local fire authorities estimated property damage at approximately 154 million Korean won. At the time of reporting, the exact cause of the fire remained under investigation by the fire department.

The battery energy storage system, which supported solar integration at the site, had a capacity of 1.2 MWh and had been in operation for under a year prior to the incident.

Not reported. Fire authorities stated the exact cause was still under investigation at the time of publication.

  1. Lithium-ion battery rooms at solar sites need early detection and suppression, as fires can destroy many units before firefighters arrive.
  2. BESS units under one year old need extra commissioning checks and monitoring, given the risk of early failure.

More lessons on detection and monitoring, from every incident on the register.

  • Exact cause of the fire
  • Battery model and supplier
  • Downtime of the solar facility

This entry is updated when these are reported. Get an alert for the next one like it.

Other entries that name Cheonan

Published 2026-09-11. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in South Korea, by year, free with a credit (PNG).

Battery storage incidents in South Korea: 35 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.