Transformer explosion sparks fire, cuts power to homes in Turramurra

May 2025Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
supply cut for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Roadside kiosk on Bannockburn Road, Turramurra, Sydney's north
What
High-voltage transformer caught fire and exploded
Injuries
None reported
Response
Six fire trucks and 22 firefighters contained blaze in 30 minutes
Cause
Under investigation

A high-voltage electrical transformer at a roadside kiosk on Bannockburn Road, Turramurra, in Sydney's north, caught fire and exploded, with flames spreading towards an adjoining power pole and overhead wires. Fire and Rescue NSW crews attended and found around 11,000 volts of live electricity alight. Firefighters established a safety zone and used hose sprays from a distance to fight the fire safely, given the electrocution risk. It took six fire trucks and 22 firefighters about 30 minutes to contain the blaze, with a further 30 minutes to fully extinguish the fire and cool the transformer oil.

The incident cut power to more than 100 homes, some of which remained without electricity into the following morning. No injuries were reported. Energy officials and police are investigating the cause.

Fire and Rescue NSW suggested one possibility was that a vehicle had struck the roadside transformer, pushing it off its mount and causing an internal short circuit, though this was not confirmed as the cause.

  1. High-voltage live equipment requires a safety zone and hose sprays from a distance to avoid electrocution risk.
  2. Roadside transformers need physical protection such as bollards if vehicle impact can push them off mount and cause short circuit.

More lessons on worker safety and safe systems of work, electrical protection and isolation, from every incident on the register.

  • Exact cause of the explosion
  • Transformer model and age
  • Cost of damage and repairs

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Grid infrastructure incidents in Australia, by year, free with a credit (PNG).

Grid infrastructure incidents in Australia: 20 entries, with a free alert for the next one.

Substation and transformer fires: the counts, the latest entries and a free alert for the next one. Also: transformer explosions.

Browse the full register or submit an incident.