Large fire at Dongen commercial building releases solar panel fragments that may be sharp
May 2025Published 30 Nov 2026Responsible editor: Chief Editor
Get the next one by email
Free alerts on solar PV incidents in the Netherlands, and an email when EIR-3131 is updated. No account needed; unsubscribe in one click.
Confirm your email and every solar incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
What happened
A very large fire broke out on the evening of 4 May 2025 in a commercial building in Dongen, the Netherlands. The business works with leather, among other activities. Part of the roof, on which solar panels were installed, was on fire, and flames rose several metres above the building. The fire service chose not to fight the fire actively and let it burn under controlled conditions until it died down.
The fire was under control by about 05:30 on 5 May 2025. Foil particles from the solar panels were released by the fire and fell on the ground up to 8 kilometres away. The Midden- en West-Brabant safety region warned that these particles could be sharp. Farmers were advised to keep animals indoors temporarily and to inspect feed and drinking troughs for glass particles. Chemicals and oil were stored in the building, but the safety region said they were almost completely burnt and no raised concentrations of hazardous substances were measured. Fire crews used water from the Wilhelminakanaal. Workers on the business park were able to leave by a route set by police.
Contributing factors
The source does not state the cause of the fire or describe how the solar installation was fixed to the roof. The intense fire is reported to have released foil fragments from the panels.
Lessons learned
- Roof fires involving rooftop PV can release sharp panel fragments over a wide area, so exclusion zones and advice to keep livestock indoors and check feed should be part of the response plan.
- Where fire services decide on controlled burns, the downwind spread of debris from PV arrays should be assessed and communicated early.
- Operators and building owners of commercial sites with rooftop PV should hold current records of array locations and stored chemicals so that emergency services can plan safely.
More lessons on fire suppression and firefighting, emergency response and public communication, from every incident on the register.