Register / Solar PV / EIR-2073
← Back to the list
Solar PVAustraliaEIR-2073

Rooftop solar DC isolator catches fire on a home in New Lambton, Newcastle

2020Published 6 Oct 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersHigh confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden

In early October 2020 Fire and Rescue NSW crews attended a home in New Lambton, Newcastle, New South Wales, Australia, after a fire on the roof. They found that the rooftop solar PV isolation switch (the DC isolator mounted next to the panel array) had caught fire. Firefighters put the fire out quickly and stopped it spreading into the roof. No injuries were reported. The report noted that the isolator had some weather protection from a shroud.

The cause of the failure was not reported. The article set the incident against earlier Fire and Rescue NSW statements that solar system fires in the state had risen over five years and that DC isolator switches accounted for around half of PV fire incidents in the state. Rooftop DC isolators are required in Australia under the AS/NZS 5033 standard.

The fire started in the rooftop DC isolator switch. The specific cause of the failure was not reported. The isolator had a weather shroud fitted.

  1. Treat rooftop DC isolators as a known fire initiation point and include them in every periodic inspection and system test.
  2. Check isolator enclosures for water ingress, ultraviolet degradation and loose terminations, even where a weather shroud is fitted.
  3. Make sure occupants know how to recognise smoke or scorching around roof-mounted switchgear and to call the fire service rather than attempt to operate the switch.

More lessons on electrical protection and isolation, weather and external hazards, fire suppression and firefighting, from every incident on the register.

Other entries that name Newcastle

Published 2026-10-06. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.