Fire involving solar panels at a Market Harborough house spreads to an adjoining property

June 2026Published 28 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
Where
Carroll Street, Market Harborough
What
Fire on first floor and roof involving solar panels, spread to adjoining property
Response
Four appliances and aerial ladder platform; gas isolated by Cadent
Cause
Not reported
Outcome
Roof collapsed; fire believed out after damping down

Leicestershire Fire and Rescue Service received multiple calls to a building fire on Carroll Street in Market Harborough. Crews reported that one two-storey domestic dwelling was involved in a fire involving solar panels, with fire on the first floor and the roof, and that it had spread to an adjoining property. Breathing apparatus, hose reels and jets were used. The gable was unstable and the roof collapsed, and crews later worked from outside because of structural instability and a risk of stair collapse.

All persons were accounted for. The gas supplier attended and isolated the gas supply. Electricity was requested to attend; the log does not say whether that supply was isolated. The stop message said the fire was believed out, with damping down under way and further inspections planned.

The cause was not reported. The log records a fire involving solar panels, an unstable gable and a collapsed roof, but it does not state what started the fire.

  1. Confirm isolation of the building electricity supply and any solar PV system early, and record what has actually been isolated.
  2. Reassess roof and gable stability when fire involves a roof with solar panels, and move crews outside if collapse is a risk.
  3. Check adjoining properties quickly when fire has spread from a roof.

More lessons on electrical protection and isolation, structural integrity and turbines, spacing, layout and fire spread, from every incident on the register.

  • How the fire started
  • Whether solar panels were the origin
  • Whether electricity supply was isolated
  • Cost of the damage

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-28. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Solar PV incidents in the United Kingdom, by year, free with a credit (PNG).

Solar PV incidents in the United Kingdom: 97 entries, with a free alert for the next one.

Solar farm fires: the counts, the latest entries and a free alert for the next one. Also: rooftop solar fires.

Browse the full register or submit an incident.