Worker killed by falling turbine blade at Golden Plains wind farm in Australia
Nov 2024Published 15 Sept 2026Responsible editor: Chief Editor
- Where
- Golden Plains Wind Farm near Rokewood, Victoria
- What
- Worker killed by falling turbine blade during assembly
- Injuries
- One worker killed
- Cause
- Not reported
Get the next one by email
Free alerts on wind (onshore) incidents in Australia, and an email when EIR-0750 is updated. No account needed; unsubscribe in one click.
Confirm your email and every wind turbine incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
Companies named in the reporting of this entry (being named is not a finding of fault): Vestas
What happened
A 36-year-old worker was killed on 11 November 2024 at the Golden Plains Wind Farm near Rokewood, Victoria. According to published reporting, a wind turbine blade came loose from scaffolding during assembly and crushed him. The worker was engaged as a subcontractor for Professional Wind Services on the project, which is being constructed by Vestas Wind Systems. The project is reported to be valued at over 3 billion Australian dollars and is intended to become Australia's largest wind farm, with more than 215 turbines and a capacity of 1,330 MW.
Union representatives said safety complaints had been raised with site management and with the state safety regulator, WorkSafe Victoria, before the fatality. WorkSafe was reported to have conducted 117 site visits to the project since March 2023 and issued 22 compliance notices to a number of duty holders. WorkSafe launched an investigation into the death, with a police inquiry also expected. The cause has not been established by any published official finding.
Contributing factors
Not established. Union representatives are reported to have raised longstanding safety concerns with site management and with WorkSafe Victoria before the fatality. Earlier reported events at the project include a turbine blade striking a crane boom in October 2024, after which the subcontractor responsible was removed from crane lifting pending investigation, and blade serrated edges detaching during a storm in September 2024 and landing on nearby properties.
Lessons learned
- Lifting and temporary support for blades during turbine assembly must include engineering review, documented inspection and a clear exclusion zone.
- Repeated safety reports and compliance notices at a construction site should trigger a site-wide review rather than isolated corrective actions.
- Earlier near misses at the same site, such as a blade striking a crane boom, should be investigated across all contractors.
More lessons on structural integrity and turbines, electrical protection and isolation, from every incident on the register.
Not yet known
- Cause of the blade detachment
- Turbine blade model and age
- Cost of the incident and downtime
This entry is updated when these are reported. Get an alert for the next one like it.
Source
Published 2026-09-15. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.