← Back to the list
Battery storageFranceEIR-0123

Container fire at Claudia battery storage site in Saucats, France

Aug 2023Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenAsset hidden years old
Where
Claudia battery storage site in Saucats, Gironde, France
Operator
Amarenco
What
Fire broke out in lithium-ion battery container during commissioning
Injuries
None reported
Response
Local fire services used water curtain for a day and night

Companies named in the reporting of this entry (being named is not a finding of fault): Amarenco, Nidec Industrial Solutions

A fire broke out in a container of lithium-ion batteries at the Claudia battery energy storage facility in Saucats (Barban), Gironde, France, which was in the process of being commissioned. The site is operated and owned by Amarenco, with the battery system integrated by Nidec Industrial Solutions. The fire started around midday and was contained over roughly a day and night by local fire services, who used a water curtain to prevent the flames spreading rather than applying water directly to the burning battery unit, in line with guidance for lithium-ion fires.

No injuries were reported and the fire did not spread to nearby forest. Thick black smoke was visible several hundred metres away, prompting concern among nearby residents and farmers about potential effects on crops and woodland. Amarenco stated an investigation into the cause was ongoing, with recent hot weather and the unit having only just been brought into service considered possible factors.

Possible factors under investigation included the unit having only recently been commissioned and preceding heatwave conditions; Amarenco had not confirmed a root cause at the time of reporting.

  1. Lithium-ion battery fires in containers produce thick smoke even when contained, so operators must prepare community communication plans in advance.
  2. Fire services need pre-agreed protocols for lithium-ion units that use water curtains rather than direct water application.
  3. Newly commissioned battery units may need extra thermal checks during hot weather until root causes are known.

More lessons on emergency response and public communication, fire suppression and firefighting, weather and external hazards, from every incident on the register.

  • Root cause of the fire
  • Battery system model and age
  • Duration of site downtime
  • Cost of damage and repairs

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents by year, free with a credit (PNG).

Battery storage incidents in France: 2 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one. Also: battery storage container fires.

Browse the full register or submit an incident.