Battery storageUnited KingdomEIR-0023

Battery storage site commissioned without on site fire water provision, concern raised before any incident

2018Published 1 May 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersHigh confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hiddenAsset hidden years old
Where
Grid connected battery energy storage site in the UK
What
Commissioned without on site fire water provision
Injuries
None reported
Outcome
Fire response vulnerability identified before any incident

In 2018 a grid connected battery energy storage site in the UK was built and commissioned to operating status. An engineering practitioner later raised a formal concern through a UK collaborative safety reporting scheme, stating that there was no fire hydrant within 90 metres of the site, the nearest being about 1.7 kilometres away, and that no emergency water supply had been provided on site. The reporter stated that the absence of accessible firefighting water had not been identified during consultation with the local fire and rescue service, nor at the design and approval stages.

The scheme's expert panel reviewed the concern and published it with commentary in 2023. No fire occurred at the site, and the matter was recorded as a fire response vulnerability identified before any incident.

As stated by the reporter and the reviewing expert panel: (1) the general building fire safety guidance applied, Approved Document B, was considered not always sufficient for battery specific fire hazards, and the reporter's view was that such sites fall outside the common building situations the guidance addresses; (2) the fire and rescue service consultation carried out for the project did not identify the water supply gap, although consultation was the intended route for fire response considerations to be raised; (3) the reporter considered that suggestions to treat attenuation ponds as an emergency water supply were not an adequate substitute for dedicated fire water provision; (4) the reporter also noted that site safety signage was inadequate, with 'Danger of Death' signage not displayed on the required yellow background, which the reporter regarded as a separate departure from the Electricity Safety, Quality and Continuity Regulations 2002.

  1. Battery storage sites need dedicated fire water within 90 metres. Operators must confirm hydrant access in writing before commissioning.
  2. General building fire guidance may not cover battery thermal runaway. Check and add site specific water supply where it falls short.

More lessons on fire suppression and firefighting, worker safety and safe systems of work, from every incident on the register.

  • Exact site location
  • Battery model and age
  • Fire water volume required

This entry is updated when these are reported. Get an alert for the next one like it.

Approved Document B

Published 2026-05-01. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Battery storage incidents in the United Kingdom, by year, free with a credit (PNG).

Battery storage incidents in the United Kingdom: 9 entries, with a free alert for the next one.

Battery storage fires: the counts, the latest entries and a free alert for the next one.

Browse the full register or submit an incident.