Two complete records, nothing to fill in

Exactly as a subscriber sees them. No email, no form.

Get your pack

£295 for one project, by email in minutes.

EIR-0102 · 2025 · United States

Battery storage fire prompts evacuation order at California Flats site in Monterey County

Two independent sources
California Flats Energy Storage Project (also referred to as Solar Flats / Parkfield Solar Plant)
Parkfield area, Monterey County, California, United States
Date
30 Aug 2025
Severity
Significant
Storage
240MWh
Age
4yrs
Injuries
0
Fatalities
0
Operator
Arevon Energy
Owner
Arevon Energy
Manufacturer
Tesla
Integrator
Tesla
What happened

A thermal incident occurred at the California Flats Energy Storage Project, a battery energy storage system co-located with a large solar plant near Parkfield in Monterey County, California, operated and owned by Arevon Energy, with the battery system supplied and integrated by Tesla. The site's thermal detection system triggered and automatically alerted emergency services. Four of 84 battery units at the facility were affected; the remainder of the system was unaffected. Local fire authorities attended but were not required to take suppression action, and the fire was allowed to burn out under controlled monitoring. As a precaution, an evacuation order was issued for a small number of nearby residences within a two-mile radius, which was lifted after approximately three hours once responders confirmed there was no ongoing threat to the public. No injuries or fatalities were reported, and no private property was damaged.

Technology

Tesla Megapack lithium-ion battery storage

Root cause

Not publicly disclosed; described only as a 'thermal incident' confined to four of 84 battery units

Failed element

Four of 84 battery units (Tesla Megapacks) at the facility

Fire service response

CAL FIRE responded initially to a reported possible vegetation fire and discovered a battery fire; local fire departments dispatched to monitor the site but were not required to take suppression action; Tesla Field Services Response Team also attended and monitored the site 24/7

Regulatory action

None specifically reported for this incident, though it occurred amid broader California legislative attention (Assembly Bill 303, the 'Battery Energy Safety & Accountability Act') following the earlier Moss Landing battery storage fire in January 2025

Lessons learned

(1) Automated thermal detection at a battery storage site can alert emergency services before visible fire signs appear, allowing early site isolation. (2) A contained battery fire at a hybrid solar site can be left to burn out under monitoring when suppression risks outweigh benefits and spread is limited.

EIR-0125 · 2023 · United States

Battery storage fire at Chaumont Site 1 prompts shelter-in-place order

Two independent sources
Chaumont Site 1 / Tops Markets solar-plus-storage project
Town of Lyme, Chaumont, Jefferson County, New York, United States
Date
27 July 2023
Severity
Significant
Capacity
5MW
Storage
15MWh
Commissioned
2022
Age
0.4yrs
Injuries
0
Fatalities
0
Operator
Convergent Energy and Power
Owner
NSF Chaumont Site 1
Manufacturer
GE
Integrator
Convergent Energy and Power
What happened

In 2023 a fire was reported at an outdoor battery energy storage system co-located with a solar photovoltaic array at the Chaumont Site 1 / Tops Markets solar-plus-storage project in the Town of Lyme, Chaumont, Jefferson County, New York, United States, operated and integrated by Convergent Energy and Power and owned by NSF Chaumont Site 1. The storage system, supplied by GE, used nickel manganese cobalt (NMC) cells and was a small utility-scale installation of single-digit megawatts with a few hours of duration. Available sources indicate the system had been in service for less than six months, and it is not clear whether the wider project had reached full commercial operation. Local authorities issued a precautionary shelter-in-place order for residents within about one mile of the site while the fire was dealt with. Reported physical damage was limited to part of the installation. No injuries or fatalities were reported in available sources.

Technology

Lithium-ion (NMC referenced in register text; NYSERDA record lists chemistry generically as Li-ion)

Root cause

Provisional: village officials stated that mechanical equipment supporting the operation of the solar project malfunctioned, causing the fire; a full root cause investigation was initiated by the operator but results were not reported in available sources.

Failed element

Four lithium battery storage trailers caught fire within the battery energy storage system enclosure area.

Fire service response

Local and county fire departments, including the Chaumont Fire Department, responded and monitored the fire over multiple days; officials indicated the fire could burn for 24 to 48 hours or up to 5 to 7 days given the difficulty of extinguishing lithium-ion battery fires with water. State officials were also involved in the response and subsequent investigation.

Regulatory action

The New York governor announced the creation of a new inter-agency fire safety council/task force to work with first responders on battery storage safety following this and two earlier 2023 New York battery storage fires.

Lessons learned

(1) Where a new battery system is in its first months of service, agree in writing which party monitors cell data and who may isolate the unit out of hours. (2) Emergency plans for storage sites near housing must set trigger conditions and communication routes for shelter-in-place orders in advance. (3) At co-located solar and storage sites, response plans must cover how to isolate direct current sources that remain live in daylight.

Why these two are shown in full. Every entry on the register names the site and the companies as the public reporting names them. What a subscriber gets is the structured record behind the entry, and these two show it in full. Which entries appear here is an explicit list, not a rule.

What people use it for

Underwriting and pricing

Frequency and severity by technology, OEM and age, with the loss and downtime data behind each event.

Lending due diligence

Has this integrator, OEM or operator had verified incidents, and what happened next.

Procurement

Failure elements and root causes by supplier before you sign.

Planning and permitting

Evidence of how comparable sites have performed, with sources a planning officer can check.

Want three for your own segment? Records chosen for underwriting, lending, procurement or operations, sent by email within a minute, plus the current benchmark table. No call, no obligation.

The same entry, free and paid

Compare a live entry from the free register with the fields subscribers see behind it.

Free register entry (live)

Battery storage fire prompts evacuation order at California Flats site in Monterey County
EIR-0102 | Hybrid co-located | 2025

A thermal incident occurred at the California Flats Energy Storage Project, a battery energy storage system co-located with a large solar plant near Parkfield in Monterey County, California, operated and owned by Arevon Energy, with the battery system supplied and integrated by Tesla. The site's thermal detection system triggered and automatically alerted emergency services. Four of 84 battery units at the facility w...

The public entry says what happened, with the site and the companies named as the reporting names them. The verified record above adds the structured fields, the figures and every source.