Wind (onshore)United StatesEIR-0335

Nacelle fire damages turbine at Waymart Wind Farm near Browndale, Pennsylvania

Mar 2026Published 7 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
turbine out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
Waymart Wind Farm near Browndale, Pennsylvania
Owner
Sequitur Renewables
What
Nacelle fire on one turbine
Injuries
None reported
Cause
Not reported

Companies named in the reporting of this entry (being named is not a finding of fault): Sequitur Renewables

On the evening of 9 March 2026, residents near Browndale, Pennsylvania, saw one of the 43 turbines at the Waymart Wind Farm, owned by Sequitur Renewables, on fire. The blaze was seen coming from the nacelle, the housing behind the blades that contains the gearbox, generator and electrical systems. Local fire officials were alerted and Browndale Fire Company and Waymart Volunteer Fire Department responded, with Forest City Area Emergency Services on standby.

Given the turbine's remote ridge location and the presence of snowpack limiting fire spread, officials and wind farm personnel decided to let the fire burn itself out rather than attempt suppression. Fire crews left the scene at around 9pm, roughly two to two and a half hours after the fire began. No injuries were reported. Sequitur Renewables personnel were due to inspect the turbine afterwards to assess damage and plan recovery. A cause had not been released at the time of reporting.

The turbine's remote ridge-top location and limited access made direct firefighting impractical, and responders judged that surrounding snowpack reduced the risk of the fire spreading to nearby vegetation, so it was allowed to burn out under monitoring.

  1. Remote ridge-top turbines with limited access require pre-agreed protocols on when to let a fire burn out rather than attempt suppression.
  2. Snowpack around a turbine site can reduce fire spread risk and support a monitored burn-out decision.
  3. Local volunteer fire services often reach remote turbines first, so operators need clear communication links with them.

More lessons on fire suppression and firefighting, weather and external hazards, from every incident on the register.

  • Turbine model and age
  • Cause of the fire
  • Extent of damage and recovery cost
  • Duration of turbine downtime

This entry is updated when these are reported. Get an alert for the next one like it.

Site page: Waymart Wind (status, dates and other incidents)

Published 2026-09-07. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Wind (onshore) incidents in the United States, by year, free with a credit (PNG).

Wind (onshore) incidents in the United States: 102 entries, with a free alert for the next one.

Wind turbine fires: the counts, the latest entries and a free alert for the next one. Also: wind turbine blade failures and wind turbine nacelle fires.

Browse the full register or submit an incident.