Warehouse operator takes US rooftop solar offline after six fires or arc-flash events

2020Published 28 Sept 2026Responsible editor: Chief Editor

Estimated damageEstimated by the register's adjusterHow? Know the real figure?
Figure hidden: shown to subscribersMedium confidence
out of service for about •• daysShown in the record →Full estimate
From the recordRoot cause hiddenFailed part hidden
Where
47 North American warehouse sites
What
Six fires or arc-flash events in fourteen months
Response
Three-alarm fire in Fresno and two-alarm fire in Perryville
Outcome
All rooftop arrays taken offline by June 2021

Between April 2020 and June 2021, a warehouse operator had six fires or arc-flash events at rooftop solar on 47 North American sites. The first, on 14 April 2020, was a three-alarm fire at a fulfilment centre in Fresno that damaged 220 modules. About fourteen months later a two-alarm fire at Perryville, Maryland, drew in around sixty firefighters. By June 2021 every US rooftop array had been taken offline. An outside inspection then reported one critical finding and 259 major findings. That audit covered rooftops in the United States, Asia Pacific and Europe, the Middle East and Africa, not only the 47 North American sites.

The inspection reported mismatched connectors, connectors installed incorrectly, poor wire management and water inside inverters. The source says none of these was a panel defect. It does not identify the operator.

  1. Mating connectors should be of the same type and brand, or listed and identified for intermatability, before they are joined.
  2. Large rooftop arrays contain many handmade joints that can loosen with heat, weather and poor wire management, so connectors, leads and inverters need periodic inspection.
  3. Water inside inverters and leads left free to rub on racking should be treated as fire risks, not only as losses of generation.

More lessons on maintenance, inspection and ageing assets, weather and external hazards, from every incident on the register.

  • Which factors applied to each of the six events
  • Operator name
  • Equipment model and age

This entry is updated when these are reported. Get an alert for the next one like it.

Published 2026-09-28. Written from public reporting. Descriptive, not investigative. See the data accuracy disclaimer.

See the register's stories first in Google: add it as a preferred source.

Chart to reuse with this story: Solar PV incidents in the United States, by year, free with a credit (PNG).

Solar PV incidents in the United States: 154 entries, with a free alert for the next one.

Solar farm fires: the counts, the latest entries and a free alert for the next one. Also: rooftop solar fires.

Browse the full register or submit an incident.