Solar panels spark roof fire at New Bedford RMV
July 2019Published 25 Sept 2026Responsible editor: Chief Editor
- Where
- Registry of Motor Vehicles, North End business park, New Bedford, 9 July 2019
- What
- Roof fire sparked by solar panels, five or ten affected
- Injuries
- None reported
- Response
- New Bedford Fire Department knocked down fire and attempted power shutdown
- Cause
- Under investigation
Get the next one by email
Free alerts on solar PV incidents in the United States, and an email when EIR-1242 is updated. No account needed; unsubscribe in one click.
Confirm your email and every solar incident on the register arrives at once as a spreadsheet (CSV), free.
Get a free sample brief Three complete verified records and the incidents-per-GW table, by email within a minute.
We will also email you about the register's paid records and plans, at most once a week and three times in all. You can stop these at any time. By signing up you agree to the privacy policy.
What happened
On the afternoon of 9 July 2019 the New Bedford Fire Department responded to a roof fire at the Registry of Motor Vehicles in the North End business park. A fire officer told the station that solar panels had sparked the blaze, affecting about five or ten panels among hundreds. Crews had knocked the fire down and were attempting to shut down power to the building and checking for any spread. Some water damage inside the building was reported, but its extent was not known. No injuries were reported. The fire remained under investigation.
Contributing factors
The fire department said solar panels sparked the blaze. No further cause was reported, and the fire was still under investigation.
Lessons learned
- A rooftop solar array fire can affect only five or ten panels yet still leave the roof unsafe until power is isolated and spread is checked.
- Crews should treat isolation of a live solar array as incomplete until shutdown is confirmed, not merely attempted.
- Water used on a roof fire with solar panels can damage the building below, so internal damage must be assessed after the fire is out.
More lessons on spacing, layout and fire spread, electrical protection and isolation, from every incident on the register.
Not yet known
- Exact cause of the solar panel failure
- Solar array model and age
- Cost of damage and downtime
This entry is updated when these are reported. Get an alert for the next one like it.